Hand-eye calibration

For applications, in which the camera is integrated into one or more robot systems, it needs to be calibrated w.r.t. some robot reference frames. For this purpose, the rc_visard is shipped with an on-board calibration routine called the hand-eye calibration component.

Note

The implemented calibration routine is completely agnostic about the user-defined robot frame to which the camera is calibrated. It might be a robot’s end-effector (e.g., flange or tool center point) or any point on the robot structure. The method’s only requirement is that the pose (i.e., translation and rotation) of this robot frame w.r.t. a user-defined external reference frame (e.g., world or robot mounting point) is exactly observable by the robot controller and can be reported to the calibration component.

The Calibration routine itself is an easy-to-use three-step procedure using a calibration grid which can be obtained from Roboception.

Calibration interfaces

The following two interfaces are offered to conduct hand-eye calibration:

  1. All services and parameters of this component required to conduct the hand-eye calibration programmatically are exposed by the rc_visard’s REST-API interface. The respective node name of this component is rc_hand_eye_calibration and the respective service calls are documented Services.

    Note

    The described approach requires a network connection between the rc_visard and the robot controller to pass robot poses from the controller to the rc_visard’s calibration component.

  2. For use cases where robot poses cannot be passed programmatically to the rc_visard’s hand-eye calibration component, the Web GUI’s Hand-Eye Calibration tab offers a guided process to conduct the calibration routine manually.

    Note

    During the process, the described approach requires the user to manually enter into the Web GUI robot poses, which need to be accessed from the respective robot-teaching or handheld device.

Camera mounting

As illustrated in Fig. 34 and Fig. 36, two different use cases w.r.t. to the mounting of the camera generally have to be considered:

  1. The camera is mounted on the robot, i.e., it is mechanically fixed to a robot link (e.g., at its flange or a flange-mounted tool), and hence moves with the robot.
  2. The camera is not mounted on the robot but is fixed to a table or other place in the robot’s vicinity and remains at a static position w.r.t. the robot.

While the general Calibration routine is very similar in both use cases, the calibration process’s output, i.e., the resulting calibration transform, will be semantically different, and the fixture of the calibration grid will also differ.

Calibration with a robot-mounted camera

When calibrating a robot-mounted camera with the robot, the calibration grid has to be secured in a static position w.r.t. the robot, e.g., on a table or some other fixed-base coordinate system as sketched in Fig. 34.

Warning

It is extremely important that the calibration grid does not move during step 2 of the Calibration routine. Securely fixing its position to prevent unintended movements such as those caused by vibrations, moving cables, or the like is therefore strongly recommended.

The result of the calibration (step 3 of the Calibration routine) is a pose \(\mathbf{T}^{\text{robot}}_{\text{camera}}\) describing the (previoulsy unknown) relative positional and rotational transformation from the camera frame into the user-selected robot frame such that

(3)\[\mathbf{p}_{\text{robot}} = \mathbf{R}^{\text{robot}}_{\text{camera}} \cdot \mathbf{p}_{\text{camera}} + \mathbf{t}^{\text{robot}}_{\text{camera}} \:,\]

where \(\mathbf{p}_{\text{robot}} = (x,y,z)^T\) is a 3D point with its coordinates expressed in the robot frame, \(\mathbf{p}_{\text{camera}}\) is the same point represented in the camera coordinate frame, and \(\mathbf{R}^{\text{robot}}_{\text{camera}}\) as well as \(\mathbf{t}^{\text{robot}}_{\text{camera}}\) are the corresponding \(3\times 3\) rotation matrix and \(3\times 1\) translation vector of the pose \(\mathbf{T}^{\text{robot}}_{\text{camera}}\), respectively. In practise, in the calibration result and in the provided robot poses, the rotation is defined by Euler angles or as quaternion instead of a rotation matrix (see Pose formats).

_images/sketch_handeye_calib_robotmounted.svg

Fig. 34 Important frames and transformations for calibrating a camera that is mounted on a general robot. The camera is mounted with a fixed relative position to a user-defined robot frame (e.g., flange or TCP). It is important that the pose \(\mathbf{T}^{\text{ext}}_{\text{robot}}\) of this robot frame w.r.t. a user-defined external reference frame ext is observable during the calibration routine. The result of the calibration process is the desired calibration transformation \(\mathbf{T}^{\text{robot}}_{\text{camera}}\), i.e., the pose of the camera frame within the user-defined robot frame.

Additional user input is required if the movement of the robot is constrained and the robot can rotate the Tool Center Point (TCP) only around one axis. This is typically the case for robots with four Degrees Of Freedom (4DOF) that are often used for palletizing tasks. In this case, the user must specify which axis of the robot frame is the rotation axis of the TCP. Further, the signed offset from the TCP to the camera coordinate system along the TCP rotation axis has to be provided. Fig. 35 illustrates the situation.

For rc_visard, the camera coordinate system is located in the optical center of the left camera. The approximate location is given in section Coordinate frames.

_images/sketch_handeye_calib_robotmounted_4dof.svg

Fig. 35 In case of a 4DOF robot, the TCP rotation axis and the offset from the TCP to the camera coordinate system along the TCP rotation axis must be provided. In the illustrated case, this offset is negative.

Calibration with a statically-mounted camera

In use cases where the camera is positioned statically w.r.t. the robot, the calibration grid needs to be mounted to the robot as shown for example in Fig. 36 and Fig. 37.

Note

The hand-eye calibration component is completely agnostic about the exact mounting and positioning of the calibration grid w.r.t. the user-defined robot frame. That means, the relative positioning of the calibration grid to that frame neither needs to be known, nor it is relevant for the calibration routine, as shown in Fig. 37.

Warning

It is extremely important that the calibration grid is attached securely to the robot such that it does not change its relative position w.r.t. the user-defined robot frame during step 2 of the Calibration routine.

In this use case, the result of the calibration (step 3 of the Calibration routine) is the pose \(\mathbf{T}^{\text{ext}}_{\text{camera}}\) describing the (previoulsy unknown) relative positional and rotational transformation between the camera frame and the user-selected external reference frame ext such that

(4)\[\mathbf{p}_{\text{ext}} = \mathbf{R}^{\text{ext}}_{\text{camera}} \cdot \mathbf{p}_{\text{camera}} + \mathbf{t}^{\text{ext}}_{\text{camera}} \:,\]

where \(\mathbf{p}_{\text{ext}} = (x,y,z)^T\) is a 3D point with its coordinates expressed in the external reference frame ext, \(\mathbf{p}_{\text{camera}}\) is the same point represented in the camera coordinate frame, and \(\mathbf{R}^{\text{ext}}_{\text{camera}}\) as well as \(\mathbf{t}^{\text{ext}}_{\text{camera}}\) are the corresponding \(3\times 3\) rotation matrix and \(3\times 1\) translation vector of the pose \(\mathbf{T}^{\text{ext}}_{\text{camera}}\), respectively. In practise, in the calibration result and in the provided robot poses, the rotation is defined by Euler angles or as quaternion instead of a rotation matrix (see Pose formats).

_images/sketch_handeye_calib_static.svg

Fig. 36 Important frames and transformations for calibrating a statically mounted camera: The latter is mounted with a fixed position relative to a user-defined external reference frame ext (e.g., the world coordinate frame or the robot’s mounting point). It is important that the pose \(\mathbf{T}^{\text{ext}}_{\text{robot}}\) of the user-defined robot frame w.r.t. this frame is observable during the calibration routine. The result of the calibration process is the desired calibration transformation \(\mathbf{T}^{\text{ext}}_{\text{camera}}\), i.e., the pose of the camera frame in the user-defined external reference frame ext.

_images/sketch_handeye_calib_gridmount.svg

Fig. 37 Alternate mounting options for attaching the calibration grid to the robot

Additional user input is required if the movement of the robot is constrained and the robot can rotate the Tool Center Point (TCP) only around one axis. This is typically the case for robots with four Degrees Of Freedom (4DOF) that are often used for palletizing tasks. In this case, the user must specify which axis of the robot frame is the rotation axis of the TCP. Further, the signed offset from the TCP to the visible surface of the calibration grid along the TCP rotation axis has to be provided. The grid must be mounted such that the TCP rotation axis is orthogonal to the grid. Fig. 38 illustrates the situation.

_images/sketch_handeye_calib_static_4dof.svg

Fig. 38 In case of a 4DOF robot, the TCP rotation axis and the offset from the TCP to the visible surface of the grid along the TCP rotation axis must be provided. In the illustrated case, this offset is negative.

Calibration routine

The general hand-eye calibration routine consists of three steps, which are illustrated in Fig. 39. These three steps are also represented in the Web GUI’s guided hand-eye-calibration process.

_images/sketch_handeye_calib_procedure.svg

Fig. 39 Illustration of the three different steps involved in the hand-eye calibration routine

Step 1: Setting parameters

Before starting the actual calibration routine, the grid and mounting parameters have to be set to the component. As for the REST-API, the respective parameters are listed in Parameters.

Web GUI example:

The Web GUI offers an interface for entering these parameters during the first step of the calibration routine as shown in Fig. 40. In addition to grid size and camera mounting, the Web GUI also offers settings for calibrating 4DOF robots. In this case, the rotation axis, as well as the offset from the TCP to the camera coordinate system (robot-mounted camera) or grid surface (statically mounted camera) must be given. Finally, the pose format can be chosen, which is used for setting poses in the upcoming step 2 of the calibration process. It can be set to either XYZABC for positions and Euler angles, or XYZ+quaternion for positions plus quaternions for representing rotations. See Pose formats for the exact definitions.

Note

The Pose parameter is added to the Web GUI as a convenience option only. For reporting poses programmatically via REST-API, the XYZ+quaternion format is mandatory.

_images/webgui_hand_eye_calib1.png

Fig. 40 Defining hand-eye calibration settings via the rc_visard’s Web GUI

Step 2: Selecting and reporting robot calibration positions

In this step (2a.), the user defines several calibration positions for the robot to approach. These positions must each ensure that the calibration grid is completely visible in the left camera image. Furthermore, the robot positions need to be selected properly to achieve a variety of different perspectives for the camera to perceive the calibration grid. Fig. 41 shows a schematic recommendation of four different view points.

_images/handeyecalib-alldraw.png

Fig. 41 Recommended views on the calibration grid during the calibration procedure. In case of a 4DOF robot, other views have to be chosen, which should be as different as possible.

Warning

Calibration quality, i.e., the accuracy of the calculated calibration result, depends on the calibration-grid views provided. The more diverse the perspectives are, the better is the calibration. Choosing very similar views, i.e., varying the robot positions only slightly between different repetitions of step 2a., may lead to inaccurate estimation of the desired calibration transformation.

After the robot reaches each calibration position, the corresponding pose \(\mathbf{T}^{\text{ext}}_{\text{robot}}\) of the user-defined robot frame in the user-defined external reference frame ext needs to be reported to the hand-eye calibration component (2b.). For this purpose, the component offers different slots to store the reported poses and the corresponding left camera images. All filled slots will then be used to calculate the desired calibration transformation between the camera frame and either the user-defined robot frame (robot-mounted camera) or the user-defined external reference frame ext (static camera).

Note

To successfully calculate the hand-eye calibration transformation, at least three different robot calibration poses need to be reported and stored in slots. However, to prevent errors induced by possible inaccurate measurements, at least four calibration poses are recommended.

To transmit the poses programmatically, the component’s REST-API offers the set_pose service call (see Services).

Web GUI example:

After completing the calibration settings in step 1 and clicking Next, the Web GUI offers four different slots (First View, Second View, etc.) for the user to fill manually with robot poses. At the very top, a live stream from the camera is shown indicating whether the calibration grid is currently detected or not. Next to each slot, a figure suggests a respective dedicated viewpoint on the grid. For each slot, the robot must be operated to achieve the suggested view.

_images/webgui_hand_eye_calib2.png

Fig. 42 First sample image in the hand-eye calibration process for a statically mounted camera

Once the suggested view is achieved, the user-defined robot frame’s pose needs to be entered manually into the respective text fields, and the corresponding camera image is captured using the Take Picture to Proceed button.

Note

The user’s acquisition of robot pose data depends on the robot model and manufacturer – it might be read from a teaching or handheld device, which is shipped with the robot.

Warning

Please be careful to correctly and accurately enter the values; even small variations or typos may lead to calibration-process failure.

This procedure is repeated four times in total. Complying to the suggestions to observe the grid from above, left, front, and right, as sketched in Fig. 41, in this example the following corresponding camera images have been sent to the hand-eye calibration component with their associated robot pose:

_images/handeyecalib-allpics.png

Fig. 43 Recorded camera images as input for the calibration procedure

Step 3: Calculating and saving the calibration transformation

The final step in the hand-eye calibration routine consists of issuing the desired calibration transformation to be computed from the collected poses and camera images. The REST-API offers this functionality via the calibrate service call (see Services). Depending on the way the camera is mounted, this service computes and returns the transformation (i.e., the pose) between the camera frame and either the user-defined robot frame (robot-mounted camera) or the user-defined external reference frame ext (statically mounted camera); see Camera mounting.

To enable users to judge the quality of the resulting calibration transformation, the component also reports a calibration error \(E_{\text{camera}}\). This value is measured in pixels and denotes the root mean square of the reprojection error averaged over all calibration slots and all corners of the calibration grid. However, for a more intuitive understanding, this value can be translated into an error \(E\) at a certain distance \(Z\):

\[E = Z \frac{E_\text{camera}}{f} \:,\]

where \(f\) is the focal length in pixels.

Note

The rc_visard reports a focal length factor via its various interfaces. It relates to the image width for supporting different image resolutions. The focal length \(f\) in pixels can be easily obtained by multiplying the focal length factor by the image width in pixels.

The value \(E\) can now be interpreted as an object-related error in meters in the 3D world.

Web GUI example:

The Web GUI automatically triggers computation of the calibration result after taking the last of the four pictures. The user just needs to click the Next button to proceed to the result. The user has the possibility to specify or correct settings related to calibration of 4DOF robots if required. After changing any settings, the recompute button needs to be pressed.

In the example that is shown in Fig. 44, 4DOF is turned off and the camera is mounted statically. The resulting output is the pose of the left camera in the external coordinate system of the robot. The reported error is \(E_\text{camera}=0.29\) pixels, which corresponds to an error of approximately 0.27 mm in a distance of 1 m.

_images/webgui_hand_eye_calib3.png

Fig. 44 Result of the hand-eye calibration process displayed in the Web GUI

Parameters

The hand-eye calibration component is called rc_hand_eye_calibration in the REST-API and is represented by the Hand-Eye Calibration tab in the Web GUI. The user can change the calibration parameters there or use the REST-API interface.

Parameter overview

This component offers the following run-time parameters:

Table 17 The rc_hand_eye_calibration component’s run-time parameters
Name Type Min Max Default Description
grid_height float64 0.0 10.0 0.0 The height of the calibration pattern in meters
grid_width float64 0.0 10.0 0.0 The width of the calibration pattern in meters
robot_mounted bool false true true Whether the camera is mounted on the robot
tcp_offset float64 -10.0 10.0 0.0 Offset from TCP along tcp_rotation_axis
tcp_rotation_axis int32 -1 2 -1 -1 for off, 0 for x, 1 for y, 2 for z

Description of run-time parameters

The parameter descriptions are given with the corresponding Web GUI names in brackets.

grid_width (Grid Width (m))
Width of the calibration grid in meters. The width should be given with a very high accuracy, preferably with sub-millimeter accuracy.
grid_height (Grid Height (m))
Height of the calibration grid in meters. The height should be given with a very high accuracy, preferably with sub-millimeter accuracy.
robot_mounted (Camera Mounting)
If set to true, the camera is mounted on the robot. If set to false, the camera is mounted statically and the calibration grid is mounted on the robot.
tcp_offset (TCP Offset)
The signed offset from the TCP to the camera coordinate system (robot-mounted sensor) or the visible surface of the calibration grid (statically mounted sensor) along the TCP rotation axis in meters. This is required if the robot’s movement is constrained and it can rotate its TCP only around one axis (e.g., 4DOF robot).
tcp_rotation_axis (TCP Rotation Axis)
The axis of the robot frame around which the robot can rotate its TCP. 0 is used for X, 1 for Y and 2 for the Z axis. This is required if the robot’s movement is constrained and it can rotate its TCP only around one axis (e.g., 4DOF robot). -1 means that the robot can rotate its TCP around two independent rotation axes. tcp_offset is ignored in this case.
(Pose)
For convenience, the user can choose in the Web GUI between calibration in XYZABC format or in XYZ+quaternion format (see Pose formats). When calibrating using the REST-API, the calibration result will always be given in XYZ+quaternion.

Services

The REST-API service calls offered to programmatically conduct the hand-eye calibration and to store or restore this component’s parameters are explained below.

save_parameters

With this service call, the current parameter settings of the hand-eye calibration component are persisted to the rc_visard. That means, these values are applied even after reboot.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "return_code": {
    "message": "string",
    "value": "int16"
  }
}

reset_defaults

restores and applies the default values for this component’s parameters (“factory reset”). Does not affect the calibration result itself or any of the slots saved during calibration. Only parameters such as the grid dimensions and the mount type will be reset.

Warning

By calling this service, the current parameter settings for this component are irrecoverably lost.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "return_code": {
    "message": "string",
    "value": "int16"
  }
}

reset_calibration

deletes all previously provided poses and corresponding images. The last saved calibration result is reloaded. This service might be used to (re-)start the hand-eye calibration from scratch.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "message": "string",
  "status": "int32",
  "success": "bool"
}

set_pose

provides a robot pose as calibration pose to the hand-eye calibration routine.

The slot argument is used to assign numbers to the different calibration poses. At each instant when set_pose is called, an image is recorded. This service call fails if the grid was undetectable in the current image.

The definition for the request arguments with corresponding datatypes is:

{
  "pose": {
    "orientation": {
      "w": "float64",
      "x": "float64",
      "y": "float64",
      "z": "float64"
    },
    "position": {
      "x": "float64",
      "y": "float64",
      "z": "float64"
    }
  },
  "slot": "int32"
}

The definition for the response with corresponding datatypes is:

{
  "message": "string",
  "status": "int32",
  "success": "bool"
}
Table 18 Return codes of the set_pose service call
status success Description
1 true pose stored successfully
3 true pose stored successfully; collected enough poses for calibration, i.e., ready to calibrate
4 false calibration grid was not detected, e.g., not fully visible in camera image
8 false no image data available
12 false given orientation values are invalid

calibrate

calculates and returns the hand-eye calibration transformation with the robot poses configured by the set_pose service. save_calibration must be called to make the calibration transformation persistent.

Note

For calculating the hand-eye calibration transformation at least three robot calibration poses are required (see set_pose service). However, four calibration poses are recommended.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "error": "float64",
  "message": "string",
  "pose": {
    "orientation": {
      "w": "float64",
      "x": "float64",
      "y": "float64",
      "z": "float64"
    },
    "position": {
      "x": "float64",
      "y": "float64",
      "z": "float64"
    }
  },
  "robot_mounted": "bool",
  "status": "int32",
  "success": "bool"
}
Table 19 Return codes of the calibrate service call
status success Description
0 true calibration successful, returned calibration result
1 false not enough poses to perform calibration
2 false calibration result is invalid, please verify the input data
3 false given calibration grid dimensions are not valid
4 false insufficient rotation, tcp_offset and tcp_rotation_axis must be specified
5 false sufficient rotation available, tcp_rotation_axis must be set to -1
6 false poses are collinear

set_calibration

sets the hand-eye calibration transformation with arguments of this call. The calibration transformation is expected in the same format as returned by the calibrate and get_calibration calls. save_calibration must be called to make the calibration transformation persistent.

The definition for the request arguments with corresponding datatypes is:

{
  "pose": {
    "orientation": {
      "w": "float64",
      "x": "float64",
      "y": "float64",
      "z": "float64"
    },
    "position": {
      "x": "float64",
      "y": "float64",
      "z": "float64"
    }
  },
  "robot_mounted": "bool"
}

The definition for the response with corresponding datatypes is:

{
  "message": "string",
  "status": "int32",
  "success": "bool"
}
Table 20 Return codes of the set_calibration service call
status success Description
0 true setting the calibration transformation was successful
12 false given orientation values are invalid

save_calibration

persistently saves the result of hand-eye calibration to the rc_visard and overwrites the existing one. The stored result can be retrieved any time by the get_calibration service.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "message": "string",
  "status": "int32",
  "success": "bool"
}
Table 21 Return codes of the save_calibration service call
status success Description
0 true calibration saved successfully
1 false could not save calibration file
2 false calibration result is not available

remove_calibration

removes the persistent hand-eye calibration on the rc_visard. After this call the get_calibration service reports again that no hand-eye calibration is available.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "message": "string",
  "status": "int32",
  "success": "bool"
}
Table 22 Return codes of the get_calibration service call
status success Description
0 true removed persistent calibration, device reports as uncalibrated
1 true no persistent calibration found, device reports as uncalibrated
2 false could not remove persistent calibration

get_calibration

returns the hand-eye calibration currently stored on the rc_visard.

This service has no arguments.

The definition for the response with corresponding datatypes is:

{
  "error": "float64",
  "message": "string",
  "pose": {
    "orientation": {
      "w": "float64",
      "x": "float64",
      "y": "float64",
      "z": "float64"
    },
    "position": {
      "x": "float64",
      "y": "float64",
      "z": "float64"
    }
  },
  "robot_mounted": "bool",
  "status": "int32",
  "success": "bool"
}
Table 23 Return codes of the get_calibration service call
status success Description
0 true returned valid calibration pose
2 false calibration result is not available